Advanced Search

Show simple item record

dc.contributor.authorEsenyel, Cem Zeki
dc.contributor.authorEsenyel, Meltem
dc.contributor.authorYeşiltepe, Rıdvan
dc.contributor.authorAyanoğlu, Semih
dc.contributor.authorBülbül, Ahmet Murat
dc.contributor.authorŞırvancı, Mustafa
dc.contributor.authorKara, Ayhan Nedim
dc.date.accessioned2020-09-16T10:06:35Zen_US
dc.date.available2020-09-16T10:06:35Zen_US
dc.date.issued2003en_US
dc.identifier.issn1017-995Xen_US
dc.identifier.urihttps://hdl.handle.net/20.500.12469/3388
dc.description.abstractAmaç: Subakromiyal sıkışma sendromlu hastalarda lokal anestetik ve steroid enjeksiyonun doğru şekilde yapılmasının ağrı şiddeti ve omuz fonksiyonlarıyla, ilişkisi araştırıldı. Çalışma planı: Çalışmaya, omuz ağrısı şikayeti iki aydan fazla süren, Subakromiyal sıkışma sendromlu 48 hasta (29 kadın, 19 erkek; ort. yaş 46.5; dağılım 23-58) alındı. Enjeksiyonun istenen bölgeye ulaşıp ulaşmadığını görüntüleyebilmek için steroid ve lokal anestetik karışımına kontrast madde eklendi. Enjeksiyon, subakromiyal bursaya anterolateral bölgeden yapıldı. Enjeksiyondan hemen sonra omuz grafileri ile verilen maddelerin doğru yerde olup olmadığı araştırıldı. Enjeksiyon öncesinde, yarım saat sonra ve iki hafta sonra elde edilen görsel ağrı skalası ve Constant değerleri ve omuz hareketleri karşılaştırıldı. Sonuçlar: Enjeksiyonun 42 hastada (%87.5) subakromiyal bursaya ulaştığı; altı hastada (%12.5) ulaşmadığı saptandı. Enjeksiyondan yarım saat sonraki değerlendirmelerde, her iki hasta grubunda da anlamlı iyileşme kaydedildi (p<0.05). Bununla birlikte iki hafta sonra, enjeksiyonun subakromial bursaya ulaşmadığı hasta grubunun parametrelerinde enjeksiyon öncesi değerlere geri dönüldüğü, diğer grupta ise anlamlı iyileşmenin sürdüğü görüldü. Çıkarımlar: Başarısız enjeksiyon oranının azaltılması için görüntüleme yöntemlerinden daha fazla yararlanılması gerektiğini düşünüyoruz.en_US
dc.description.abstractObjectives: We assessed the relationship between proper placement of corticosteroid injections and subsequent shoulder function and pain in subacromial impingement syndrome. Methods: The study included 48 patients (29 women, 19 men; mean age 46.5 years; range 23 to 58 years) with subacromial impingement syndrome, whose complaints of shoulder pain lasted more than two months. To monitor the site of injection, contrast material was added to a mixture of steroid and local anesthetic solution. Injections were delivered into the subacromial bursa by an anterolateral approach. Radiographs of the joint were taken immediately afterwards to ensure the accurate placement of the injection. Shoulder function and pain were evaluated by visual pain scale, range of movement of the joint, and Constant scores before treatment, and half an hour and two weeks after the injections. Results: The injections were placed accurately in 42 patients (87%), while in six patients (12.5%), delivery to the target site failed. Statistically significant improvements were observed in both groups half an hour after the injections (p&lt;0.05). However, two weeks after the treatment evaluations showed that failure to obtain an accurate placement was associated with return to pretreatment values, while significant improvement continued in the other group. Conclusion: Failure to deliver injections to the target site may be decreased by increased utilization of visualization and imaging methods.en_US
dc.language.isoturen_US
dc.publisherTürk Ortopedi ve Travmatoloji Derneğien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAnestetik, lokalen_US
dc.subjectAğrıen_US
dc.subjectİlaç tedavisien_US
dc.subjectOmuz sıkışma sendromuen_US
dc.subjectAnti-enflamatuvar ajanlaren_US
dc.subjectEnjeksiyon, eklem içien_US
dc.subjectHareket açıklığı, eklemen_US
dc.subjectPainen_US
dc.subjectDrug Therapyen_US
dc.subjectShoulder Impingement Syndromeen_US
dc.subjectAnesthetics, Localen_US
dc.subjectAnti-Inflammatory Agentsen_US
dc.subjectInjections, Intra-Articularen_US
dc.subjectRange of Motion, Articularen_US
dc.titleSubakromiyal sıkışma sendromunda steroid enjeksiyonunun doğru şekilde uygulanması ile omuz ağrısı ve fonksiyonu arasındaki ilişkien_US
dc.typearticleen_US
dc.identifier.startpage41en_US
dc.identifier.endpage45en_US
dc.relation.journalActa Orthopaedica et Traumatologica Turcicaen_US
dc.identifier.issue1en_US
dc.identifier.volume37en_US
dc.institutionauthorŞırvancı, Mustafaen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record