Browsing by Author "Sanisoglu, I"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Conference Object Citation Count: 0Use of octopus 2 stabilization system for off-pump coronary artery bypass grafting(Medimond S R L, 2000) Güden, M; Akpmar, B; Sagbas, E; Sanisoglu, I; Aytekin, V; Bayindir, OThe early results of 126 off pump CABG procedures performed through a median sternotomy incision (OPCAB) during a period of 18 months were evaluated. The mean age was 69+/-4.3 years. There were 80 male and 46 female patients. Emergency cases and reoperations were not included. A total of 268 anatomosis were performed with a mean number of 2.12 anastomosis Per patient. Conduits used were: LITA (100%), RITA (11.1%) GSV in (84%) and radial artery in (31%) of cases. In 72% of the cases, off pump surgery was chosen because of patient risk factors such as atherosclerotic aortic disease, previous CVA or carotid artery disease, renal dysfunction, malignancy and poor LV function. There was no operative mortality. One month mortality was 3 patients (2.3%). Two died because of mesentheric ischemia. 71 patients had a control angiogram before discharge. The patency of LITA anastomosis was 100% while overall patency rate was 95%. In 43 patients were an angiogram could not be performed, a Thalium 201 stress test was performed 3 months postoperatively. 38 had a normal test while 5 patients showed signs of ischemia. These patients had a control angiogram, in four patients anastomosis were patent, but in one patient tere was a severe narrowing of a venous anastomosis to the distal right coronary which was corrected with angioplasty. In the whole series 8 patients refused to have any control examination (6.3%). Our early results suggest that off pump CABG with Octopus stabilisation can be a good alternative in high risk patients who need multiple vessel revascularisation.Article Citation Count: 7The use of stentless valves for root replacement during repair of ascending aortic aneurysms with aortic valve regurgitation(Forum Multimedia Publishing, Llc, 2002) Akpinar, B; Güden, M; Aytekin, S; Sanisoglu, I; Sagbas, E; Özbek, U; Bayramoglu, ZBackground: Early and mid-term results of stentless valves for the treatment of ascending aortic aneurysm ( AAA) were evaluated in a retrospective manner. Material and Methods: During a four-year period, 26 patients with ascending aortic aneurysms and aortic valve insuffiency underwent a total root replacement procedure using a stentless Freestyle valve (Medtronic Inc., Minneapolis MN). Mean age was 71 +/- 4 years ( range 66 to 79 years). Eight patients were in NYHA Class 2, 13 in Class 3, and 5 in Class 4. Cardiopulmonary bypass (CPB) was begun with femoral artery-right atrium (two-stage) cannulation in all cases but four, in which the right axillary artery was used. Myocardial protection was established by retrograde, cold-blood cardioplegia and direct antegrade blood cardioplegia from the right coronary ostium. The left ventricle outflow tract was constructed by using 2-0 ticron sutures and incorporating a pericardial strip in between. Coronary buttons were sewn to the xenograft with 6-0 polypropylene sutures. Meanwhile, the patient was cooled down to 18 degrees nasopharyngeal temperature and the distal anastomosis with the proximal arch was performed with a Dacron graft under total circulatory arrest (TCA), using 4-0 polypropylene sutures. During rewarming, the connection between the Freestyle valve and the Dacron graft was performed. Results: Ischemic time was 91 +/- 11 minutes and TCA time was 9 +/- 4 minutes. Operative mortality was zero, and there was one 30-day mortality (3.8%). At discharge, all 25 patients had a functional valve with low transvalvular gradients. Patients were followed for a mean period of 15 months, with one patient being lost to follow-up and one patient dying of non-cardiac causes. Follow-up was 97% complete, and echocardiographic control during the follow-up period revealed competent valves with gradients comparable to those at discharge. Two patients were screened with electron beam tomography (EBT) three years after the operation and there was no sign of wall or lea et calcification. At the end of the 15 months ( mean) follow-up, the functional capacity of the patients had improved significantly (p < 0.05). Conclusions: Our early results suggest that use of the Freestyle valve in conjunction with a Dacron tube graft can be a good alternative for patients over 65 years of age who present with ascending aortic aneurysm with aortic valve insufficiency.