Use of octopus 2 stabilization system for off-pump coronary artery bypass grafting

dc.contributor.author Güden, M
dc.contributor.author Akpmar, B
dc.contributor.author Sagbas, E
dc.contributor.author Sanisoglu, I
dc.contributor.author Aytekin, V
dc.contributor.author Bayindir, O
dc.contributor.other 01. Kadir Has University
dc.date.accessioned 2024-10-15T19:41:09Z
dc.date.available 2024-10-15T19:41:09Z
dc.date.issued 2000
dc.description.abstract The early results of 126 off pump CABG procedures performed through a median sternotomy incision (OPCAB) during a period of 18 months were evaluated. The mean age was 69+/-4.3 years. There were 80 male and 46 female patients. Emergency cases and reoperations were not included. A total of 268 anatomosis were performed with a mean number of 2.12 anastomosis Per patient. Conduits used were: LITA (100%), RITA (11.1%) GSV in (84%) and radial artery in (31%) of cases. In 72% of the cases, off pump surgery was chosen because of patient risk factors such as atherosclerotic aortic disease, previous CVA or carotid artery disease, renal dysfunction, malignancy and poor LV function. There was no operative mortality. One month mortality was 3 patients (2.3%). Two died because of mesentheric ischemia. 71 patients had a control angiogram before discharge. The patency of LITA anastomosis was 100% while overall patency rate was 95%. In 43 patients were an angiogram could not be performed, a Thalium 201 stress test was performed 3 months postoperatively. 38 had a normal test while 5 patients showed signs of ischemia. These patients had a control angiogram, in four patients anastomosis were patent, but in one patient tere was a severe narrowing of a venous anastomosis to the distal right coronary which was corrected with angioplasty. In the whole series 8 patients refused to have any control examination (6.3%). Our early results suggest that off pump CABG with Octopus stabilisation can be a good alternative in high risk patients who need multiple vessel revascularisation. en_US
dc.identifier.citationcount 0
dc.identifier.isbn 8832306247
dc.identifier.uri https://hdl.handle.net/20.500.12469/6412
dc.language.iso en en_US
dc.publisher Medimond S R L en_US
dc.relation.ispartof 49th International Congress of the European-Society-for-Cardiovascular-Surgery -- JUN 24-27, 2000 -- Dresden, GERMANY en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject [No Keyword Available] en_US
dc.title Use of octopus 2 stabilization system for off-pump coronary artery bypass grafting en_US
dc.type Conference Object en_US
dspace.entity.type Publication
gdc.coar.access metadata only access
gdc.coar.type text::conference output
gdc.description.department Kadir Has University en_US
gdc.description.departmenttemp Kadir Has Univ, Fac Med, Florence Nightingale Hosp, Dept Cardiovasc Surg, Istanbul, Turkey en_US
gdc.description.endpage 139 en_US
gdc.description.publicationcategory Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality N/A
gdc.description.startpage 131 en_US
gdc.description.woscitationindex Conference Proceedings Citation Index - Science
gdc.description.wosquality N/A
gdc.identifier.wos WOS:000089220500021
gdc.wos.citedcount 0
relation.isOrgUnitOfPublication b20623fc-1264-4244-9847-a4729ca7508c
relation.isOrgUnitOfPublication.latestForDiscovery b20623fc-1264-4244-9847-a4729ca7508c

Files