dc.description.abstractOvervoltage is one of the major issues on distribution grids with high penetration of photovoltaic (PV) generation. Overvoltage could be prevented through the control of active/reactive power of PVs. However given the high R/X ratio of low voltage feeders voltage control by using reactive power would not be as effective as using active power. Therefore active power curtailment (APC) of PVs though not desirable becomes necessary at times to prevent the overvoltage issues. Existing literature is rich in centralized and droop-based methods for APC and/or reactive power control of PVs to prevent overvoltage issues. In this context this paper revisits the most popular existing methods and evaluates the performance of droop-based and centralized methods using a typical North American 240 V low voltage feeder with 24 residential homes. In this work our key findings are: a) droop-based methods provided conservative solutions or did not eliminate the overvoltages completely b) power flow sensitivity based droop approach led to 13% more curtailment than the centralized approaches c) centralized approach had 40% less energy curtailed compared with standard droop while no overvoltages were observed and d) operating PVs at non-unity power factor in centralized approach led to 5% less energy curtailment.en_US]
dc.language.isoengen_US
dc.publisherIEEEen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPhotovoltaicen_US
dc.subjectPower Curtailmenten_US
dc.subjectDistribution Griden_US
dc.subjectOvervoltageen_US
dc.subjectInverteren_US
dc.subjectVoltage Controlen_US
dc.titleComparative Study of Active Power Curtailment Methods of PVs for Preventing Overvoltage on Distribution Feedersen_US
dc.typeconferenceObjecten_US
dc.relation.journalPower & Energy Society General Meeting (PESGM)en_US
dc.departmentFakülteler, İşletme Fakültesi, Yönetim Bilişim Sistemleri Bölümüen_US
dc.identifier.wosWOS:000457893900001en_US
dc.identifier.doi10.1109/PESGM.2018.8585526en_US
dc.identifier.scopus2-s2.0-85060810622en_US
dc.institutionauthorCeylan, Oğuzhanen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record