Evaluation of Secondhand Smoke Using Pm2.5 and Observations in a Random Stratified Sample in Hospitality Venues From 12 Cities

dc.contributor.authorKaplan, Bekir
dc.contributor.authorÇarkoğlu, Aslı
dc.contributor.authorErgör, Gül
dc.contributor.authorHayran, Mutlu
dc.contributor.authorSureda, Xisca
dc.contributor.authorCohen, Joanna E.
dc.contributor.authorNavas-Acien, Ana
dc.date.accessioned2019-06-27T08:01:22Z
dc.date.available2019-06-27T08:01:22Z
dc.date.issued2019
dc.departmentFakülteler, İktisadi, İdari ve Sosyal Bilimler Fakültesi, Psikoloji Bölümüen_US
dc.description.abstractBackground: Turkey passed a law banning smoking in all indoor public places in 2008. In response to the indoor smoking restriction many smokers may have relocated to outdoor areas of venues. The aim of this study was to evaluate air pollution related to SHS exposure in indoor and outdoor areas of hospitality venues in 12 cities in Turkey. Method: In this cross-sectional study we evaluated hospitality venues in 12 cities in Turkey. In each visited venue we evaluated a pre-specified number of study locations such as the outdoor area of the main entrance indoor areas and patios or other outdoor dining areas completely or partially covered with window walls. We measured particulate matter 2.5 (PM2.5) in those areas. Results: The fieldworkers visited 72 randomly selected hospitality venues and measured PM2.5 concentrations in 165 different locations (indoor outdoor and patios) of those venues. Overall 2573 people were observed 909 of them smoking. The median (IQR) PM2.5 concentrations were 95 (39-229) g/m(3) indoors 25 (13-48) g/m(3) outdoors and 31 g/m(3) (16-62) in the patios (p < 0.001). After adjustment each additional smoker was associated with a 2% increase in PM2.5 concentrations in patio air (GMR (95% CI): 1.02 (1.00 1.05) and a 4% increase in indoor air (GMR (95% CI): 1.04 (1.02 1.05). Conclusions: There were unhealthy levels of smoking-caused PM2.5 concentrations not only indoors but also in the patios of hospitality venues. Legislative efforts to expand the smoke-free legislation to outdoor areas adjacent to indoor public places and an action plan to increase compliance with the smoke-free policy are urgently needed in Turkey.en_US]
dc.identifier.citation6
dc.identifier.doi10.3390/ijerph16081381en_US
dc.identifier.issn1660-4601en_US
dc.identifier.issn1660-4601
dc.identifier.issue8
dc.identifier.pmid30999605en_US
dc.identifier.scopus2-s2.0-85065023370en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12469/360
dc.identifier.urihttps://doi.org/10.3390/ijerph16081381
dc.identifier.volume16en_US
dc.identifier.wosWOS:000467747100074en_US
dc.institutionauthorÇarkoğlu, Aslıen_US
dc.institutionauthorÇarkoğlu, Aslı
dc.language.isoenen_US
dc.publisherMDPIen_US
dc.relation.journalInternational Journal of Environmental Research and Public Healthen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectsecondhand smokeen_US
dc.subjectPM2.5en_US
dc.subjectTurkeyen_US
dc.subjectHospitality venueen_US
dc.titleEvaluation of Secondhand Smoke Using Pm2.5 and Observations in a Random Stratified Sample in Hospitality Venues From 12 Citiesen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication211ed1cb-2559-4c2e-b1b5-9001ccd7c139
relation.isAuthorOfPublication.latestForDiscovery211ed1cb-2559-4c2e-b1b5-9001ccd7c139

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Evaluation of Secondhand Smoke Using PM2.5 and Observations in a Random Stratified Sample in Hospitality Venues from 12 Cities.pdf
Size:
290.59 KB
Format:
Adobe Portable Document Format
Description: