Corrected Pra Positivity Rates for Hypersensitized Patients in Turkish Population With Calculated Pra-Cpra Software

dc.contributor.advisor Yelekçi, Kemal
dc.contributor.author Karadeniz, Sedat Tanju
dc.contributor.author Yelekçi, Kemal
dc.contributor.other Molecular Biology and Genetics
dc.date.accessioned 2023-10-17T20:46:21Z
dc.date.available 2023-10-17T20:46:21Z
dc.date.issued 2017
dc.department Enstitüler, Lisansüstü Eğitim Enstitüsü, Hesaplamalı Biyoloji ve Biyoinformatik Ana Bilim Dalı en_US
dc.description.abstract Yüksek PRA (Panel Reaktif Antikor) oranları, böbrek nakli şansını düşürebilir ve nakilden önce uzun süre beklemeye yol açabilir. cPRA (Hesaplamalı Panel Reaktif Antikor), kabul edilemez (uyumsuz) HLA (Human Lökosit Antijen) antijenleri temel alınarak yapılır. Bu antijenler, serumda dolaşan HLA antijenlerine karşı gelişen antikorlara ve bu antikorların antijenlere bağlanma riskine dayanılarak oluşturulmuş bir bilgisayar programı ile tanımlanır. Böylece popülasyonun antijen profili ve antijen frekansları ölçülebilir ve bu yöntem kullanılarak daha gerçekçi cPRA pozitiflik oranları elde edilebilir. Türkiye'de EFI (European Federation Immunogenetics) tarafından akredite edilmiş iki doku tipleme laboratuvarında 494 kan bağışçısının HLA antijenlerine dayanan bir bilgisayar programı geliştirdik. Verici örneklerinin doku tiplemesi YND (Yeni Nesil Dizileme) tabanlı olarak yapıldı. İstanbul Tıp Fakültesi'nde kadavradan organ nakli yapılmasını bekleyen 380 hastaya PRA tarama testi uygulandı. 48 aşırı duyarlı hastaya antikor profillerini belirlemek için (TAT) Tek Antijen Tanımlama testi yapıldı. Duyarlılaşmış hastaların mevcut yöntemlerle PRA pozitifliği ortalama %44,6, ancak cPRA yazılımı kullanılarak pozitifliği ortalama %86,2 bulundu. cPRA yazılımı kabul edilemez tüm antijenlere göre reddedilen vericilerin oranını göstermektedir. PRA pozitiflik oranının yerine, kabul edilemez antijenlerin listesi olarak sunulan duyarlılığa bağlı hesaplamalı cPRA pozitiflik oranı ihtiyaç duyulan gerçek bir değişimdir. Esas olarak, cPRA'nın uygulanması Türkiye'de birçok merkezi ve laboratuvarı, duyarlılığın standart bir ölçümü olarak benimsemeye teşvik edecektir. cPRA yazılımını kullanmak, kabul edilemez uyuşmazlık programı oluşturarak, özellikle aşırı duyarlı hastalar için daha iyi bağış yapma şansını artıracaktır. en_US
dc.description.abstract High rates of PRA (Panel Reactive Antibody) may decrease the chance of kidney transplant and may result in long-waiting periods before transplantation. The cPRA (Calculated Panel Reactive Antibody) is performed based on unacceptable HLA (Human Leukocyte Antigen) antigens. These antigens are identified by a computer program, which was created based on the antibodies that developed against the HLA antigens circulating in serum, and on the risk of binding of these antibodies to antigens. The antigen profile of the population and antigen frequencies can be measured, and more realistic cPRA positivity rates may be obtained using this method. We developed a computer program based on the HLA antigens of 494 blood donors in two tissue typing laboratory laboratories in Turkey accredited by EFI (European Federation of Immunogenetics). NGS (Next Generation Sequencing) based tissue typing of the donor samples were performed. PRA screening test was performed to 380 patients who were waiting for organ transplant from a cadaver in Istanbul University, Istanbul Faculty of Medicine. The SAB (Single Antigen Bead Assay) testing was performed to identify the antibody profiles on 48 hypersensitized patients. The mean of PRA positivity of the sensitized patients using the current methods were found as 44.6%, however, the rate was found as 86.2% using the cPRA software. cPRA software shows the rate of the rejected donors according to all unacceptable antigens. The need for a list of unacceptable antigens, in place of the PRA positivity rate, is a real change in the sensitization dependent calculation as in cPRA positivity rate. In principal, implementation of cPRA will encourage many centers and laboratories to adopt a standard measurement of sensitization in Turkey. It will increase the chances of finding a better donor particularly for hypersensitized patients, by the creation of an unacceptable mismatch program using cPRA software. en_US
dc.identifier.endpage 45 en_US
dc.identifier.startpage 1 en_US
dc.identifier.uri https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=7lOJX8w_8PRQU1mSHU6-jugh-XM9b8pvdtN7JP2ze1ndJzC0s7GUtovKxnVINRlx
dc.identifier.uri https://hdl.handle.net/20.500.12469/4509
dc.identifier.yoktezid 470076 en_US
dc.institutionauthor Karadeniz, Sedat Tanju
dc.khas 20231017-Tez rn_US
dc.language.iso en en_US
dc.publisher Kadir Has Üniversitesi en_US
dc.relation.publicationcategory Tez en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Genetik en_US
dc.subject Genetics ; Mühendislik Bilimleri en_US
dc.title Corrected Pra Positivity Rates for Hypersensitized Patients in Turkish Population With Calculated Pra-Cpra Software en_US
dc.title.alternative Türk Popülasyonundaki Hipersensitize Hastaların Hesaplamalı Pra Cpra Yazılımı ile Düzeltilmiş Pra Oranları en_US
dc.type Master Thesis en_US
dspace.entity.type Publication
relation.isAuthorOfPublication 9407938e-3d31-453b-9199-aaa8280a66c5
relation.isAuthorOfPublication.latestForDiscovery 9407938e-3d31-453b-9199-aaa8280a66c5
relation.isOrgUnitOfPublication 71ce8622-7449-4a6a-8fad-44d881416546
relation.isOrgUnitOfPublication.latestForDiscovery 71ce8622-7449-4a6a-8fad-44d881416546

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
470076.pdf
Size:
1.5 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text

Collections