Re-Considering the Energy Efficient Retrofitting Approach To Question Cost-Optimality and Nzeb Under Covid-19 Measures

dc.contributor.author Yilmaz, Burcu Cigdem
dc.contributor.author Yilmaz, Yigit
dc.contributor.other Interior Architecture and Environmental Design
dc.contributor.other 06. Faculty of Art and Design
dc.contributor.other 01. Kadir Has University
dc.date.accessioned 2023-10-19T15:12:11Z
dc.date.available 2023-10-19T15:12:11Z
dc.date.issued 2022
dc.description.abstract The building energy performance has been highly studied in the last decades considering the indoor environmental quality, and sustainability indicators to examine energy-efficient cost-optimal, and nZEB building levels for different building typologies. However, since the start of the COVID-19 pandemic in 2020, the usage and operation of public spaces and buildings have evolved according to COVID-19 measures produced by the authorities. Social distancing measures and HVAC system measures affecting energy performance and indoor environmental quality of the public buildings are consequently necessary for building energy performance studies. Thereby, it is aimed at re-considering an energy-efficient cost-optimal retrofitting approach for a primary school building case, under the COVID-19 measures to recast an energy-efficient cost-optimal level and apply a cost-efficiency criterion to search for the measures adapted nZEB scenarios. COVID-19 measures affecting building energy performance, such as social distancing and IEQ requirements, were analysed. Then, probable ventilation rates were controlled by the infection probability method to satisfy the limit number for infection. Thus, pre-COVID-19 and post-COVID-19 variables regarding occupancy density and HVAC operation were determined for the calculation process. Besides, retrofit scenarios were shaped to improve optic and thermophysical properties of the facade, lighting, and HVAC systems performance. Then, energy, LCC, thermal comfort and IEQ performance of retrofit scenarios were calculated with a calibrated model. Results were evaluated by applying the cost-efficiency criterion to find out nZEB scenarios. It can be stated that distinct LCC and energy use increments occurred in the cost-optimal range and nZEB level. en_US
dc.identifier.citationcount 6
dc.identifier.doi 10.1016/j.buildenv.2022.109227 en_US
dc.identifier.issn 0360-1323
dc.identifier.issn 1873-684X
dc.identifier.scopus 2-s2.0-85131131476 en_US
dc.identifier.uri https://doi.org/10.1016/j.buildenv.2022.109227
dc.identifier.uri https://hdl.handle.net/20.500.12469/5371
dc.khas 20231019-WoS en_US
dc.language.iso en en_US
dc.publisher Pergamon-Elsevier Science Ltd en_US
dc.relation.ispartof Building and Environment en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Heat-Pump System En_Us
dc.subject Educational Buildings En_Us
dc.subject Comfort En_Us
dc.subject School En_Us
dc.subject Retrofitting en_US
dc.subject Cost optimality en_US
dc.subject Heat-Pump System
dc.subject COVID-19 measures en_US
dc.subject Educational Buildings
dc.subject nZEB en_US
dc.subject Comfort
dc.subject Thermal comfort en_US
dc.subject School
dc.subject Infection probability en_US
dc.title Re-Considering the Energy Efficient Retrofitting Approach To Question Cost-Optimality and Nzeb Under Covid-19 Measures en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Yilmaz, Yigit/0000-0001-8693-2789
gdc.author.id Yilmaz, Burcu Cigdem/0000-0001-8786-4618
gdc.author.institutional Yılmaz, Burcu Çiğdem
gdc.author.wosid Yilmaz, Burcu/HZK-1308-2023
gdc.author.wosid Yilmaz, Yigit/AGZ-2707-2022
gdc.bip.impulseclass C4
gdc.bip.influenceclass C5
gdc.bip.popularityclass C4
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.departmenttemp [Yilmaz, Burcu Cigdem] Kadir Has Univ, Fac Art & Design, Istanbul, Turkey; [Yilmaz, Yigit] Bahcesehir Univ, Fac Architecture & Design, TR-34538 Istanbul, Turkey en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q1
gdc.description.startpage 109227
gdc.description.volume 219 en_US
gdc.description.wosquality Q1
gdc.identifier.openalex W4281571475
gdc.identifier.wos WOS:000896593100001 en_US
gdc.oaire.diamondjournal false
gdc.oaire.impulse 8.0
gdc.oaire.influence 3.0429497E-9
gdc.oaire.isgreen false
gdc.oaire.keywords School
gdc.oaire.keywords COVID-19 measures
gdc.oaire.keywords Thermal comfort
gdc.oaire.keywords Comfort
gdc.oaire.keywords Retrofitting
gdc.oaire.keywords Educational Buildings
gdc.oaire.keywords Cost optimality
gdc.oaire.keywords nZEB
gdc.oaire.keywords Infection probability
gdc.oaire.keywords Heat-Pump System
gdc.oaire.popularity 6.9463035E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0211 other engineering and technologies
gdc.oaire.sciencefields 02 engineering and technology
gdc.oaire.sciencefields 0202 electrical engineering, electronic engineering, information engineering
gdc.openalex.fwci 1.096
gdc.openalex.normalizedpercentile 1.0
gdc.openalex.toppercent TOP 1%
gdc.opencitations.count 8
gdc.plumx.crossrefcites 1
gdc.plumx.mendeley 56
gdc.plumx.newscount 1
gdc.plumx.scopuscites 10
gdc.scopus.citedcount 10
gdc.wos.citedcount 9
relation.isAuthorOfPublication d884eba4-36ff-492b-9215-33ee6ec045ba
relation.isAuthorOfPublication.latestForDiscovery d884eba4-36ff-492b-9215-33ee6ec045ba
relation.isOrgUnitOfPublication 0a9f6edd-770d-4882-af28-4100f62c19f0
relation.isOrgUnitOfPublication 8fe856d9-ed4d-45d5-8d18-d900eb9c3bff
relation.isOrgUnitOfPublication b20623fc-1264-4244-9847-a4729ca7508c
relation.isOrgUnitOfPublication.latestForDiscovery 0a9f6edd-770d-4882-af28-4100f62c19f0

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
5371.pdf
Size:
1.15 MB
Format:
Adobe Portable Document Format
Description:
Tam Metin / Full Text