Corneal ring segments (INTACS) for the treatment of asymmetrical astigmatism of the keratoconus. Follow-up after 2 years;

dc.authorscopusid7801695427
dc.authorscopusid35180901300
dc.authorscopusid7102013775
dc.authorscopusid6602607587
dc.contributor.authorTunc,Z.
dc.contributor.authorDeveci,N.
dc.contributor.authorSener,B.
dc.contributor.authorBahcecioglu,H.
dc.date.accessioned2024-10-15T19:41:12Z
dc.date.available2024-10-15T19:41:12Z
dc.date.issued2003
dc.departmentKadir Has Universityen_US
dc.department-tempTunc Z., Service d'Ophtalmologie, Kadir Has University, Istanbul, Turkey, Sayhan Sit DB1 Ulus, 80840 Istanbul, Gürcü Kizi Sok, Turkey; Deveci N., Service d'Ophtalmologie, Kadir Has University, Istanbul, Turkey; Sener B., Service d'Ophtalmologie, Kadir Has University, Istanbul, Turkey; Bahcecioglu H., Service d'Ophtalmologie, Kadir Has University, Istanbul, Turkeyen_US
dc.description.abstractObjective: To evaluate the use of corneal ring segments (INTACS) for the treatment of asymmetrical astigmatism in keratoconus. Material and methods: This prospective study involved nine eyes of seven patients who were operated on between December 1998 and June 2000. A case of keratoconus with opacified cornea was excluded from this study. The patients chosen were contact lens-intolerant. The surgical intervention was carried out under topical anesthesia. The INTACS (Addition Technology) corneal ring insert was inserted approximately 68% of the peripheral corneal depth and was centered to the cone of the cornea. Results: No intraoperative complications occurred. We noted a flattening of the central cornea and a decrease in irregular astigmatism for all patients. Mean preoperative uncorrected visual acuity was less than 1/10. Postoperatively two eyes had an uncorrected visual acuity of 10/10, seven eyes showed an improvement from an uncorrected visual acuity of 2/10 to 7/10. Conclusion: We have observed that the flattening effect of INTACS inserts on the soft corneal keratoconic tissue and on the high astigmatic tissue seems greater than that produced in normal cornea. Implantation of INTACS resulted in a significant reduction in asymmetrical astigmatism of the keratoconus.en_US
dc.identifier.citation17
dc.identifier.doi[SCOPUS-DOI-BELIRLENECEK-67]
dc.identifier.endpage830en_US
dc.identifier.issn0181-5512
dc.identifier.issue8en_US
dc.identifier.pmid14586224
dc.identifier.scopus2-s2.0-0242268126
dc.identifier.scopusqualityQ3
dc.identifier.startpage824en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12469/6418
dc.identifier.volume26en_US
dc.identifier.wosqualityQ4
dc.language.isofren_US
dc.relation.ispartofJournal Francais d'Ophtalmologieen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAstigmatismen_US
dc.subjectINTACSen_US
dc.subjectKeratoconusen_US
dc.titleCorneal ring segments (INTACS) for the treatment of asymmetrical astigmatism of the keratoconus. Follow-up after 2 years;en_US
dc.title.alternativeAnneaux intracornéens (INTACS) pour le traitement de l'astigmatisme asymétrique du kératocône. Recul de plus de deux ansen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files