Corneal Ring Segments (intacs) for the Treatment of Asymmetrical Astigmatism of the Keratoconus. Follow-Up After 2 Years;

dc.authorscopusid 7801695427
dc.authorscopusid 35180901300
dc.authorscopusid 7102013775
dc.authorscopusid 6602607587
dc.contributor.author Tunc,Z.
dc.contributor.author Deveci,N.
dc.contributor.author Sener,B.
dc.contributor.author Bahcecioglu,H.
dc.date.accessioned 2024-10-15T19:41:12Z
dc.date.available 2024-10-15T19:41:12Z
dc.date.issued 2003
dc.department Kadir Has University en_US
dc.department-temp Tunc Z., Service d'Ophtalmologie, Kadir Has University, Istanbul, Turkey, Sayhan Sit DB1 Ulus, 80840 Istanbul, Gürcü Kizi Sok, Turkey; Deveci N., Service d'Ophtalmologie, Kadir Has University, Istanbul, Turkey; Sener B., Service d'Ophtalmologie, Kadir Has University, Istanbul, Turkey; Bahcecioglu H., Service d'Ophtalmologie, Kadir Has University, Istanbul, Turkey en_US
dc.description.abstract Objective: To evaluate the use of corneal ring segments (INTACS) for the treatment of asymmetrical astigmatism in keratoconus. Material and methods: This prospective study involved nine eyes of seven patients who were operated on between December 1998 and June 2000. A case of keratoconus with opacified cornea was excluded from this study. The patients chosen were contact lens-intolerant. The surgical intervention was carried out under topical anesthesia. The INTACS (Addition Technology) corneal ring insert was inserted approximately 68% of the peripheral corneal depth and was centered to the cone of the cornea. Results: No intraoperative complications occurred. We noted a flattening of the central cornea and a decrease in irregular astigmatism for all patients. Mean preoperative uncorrected visual acuity was less than 1/10. Postoperatively two eyes had an uncorrected visual acuity of 10/10, seven eyes showed an improvement from an uncorrected visual acuity of 2/10 to 7/10. Conclusion: We have observed that the flattening effect of INTACS inserts on the soft corneal keratoconic tissue and on the high astigmatic tissue seems greater than that produced in normal cornea. Implantation of INTACS resulted in a significant reduction in asymmetrical astigmatism of the keratoconus. en_US
dc.identifier.citationcount 17
dc.identifier.endpage 830 en_US
dc.identifier.issn 0181-5512
dc.identifier.issue 8 en_US
dc.identifier.pmid 14586224
dc.identifier.scopus 2-s2.0-0242268126
dc.identifier.scopusquality Q3
dc.identifier.startpage 824 en_US
dc.identifier.uri https://hdl.handle.net/20.500.12469/6418
dc.identifier.volume 26 en_US
dc.identifier.wosquality Q4
dc.language.iso fr en_US
dc.relation.ispartof Journal Francais d'Ophtalmologie en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 17
dc.subject Astigmatism en_US
dc.subject INTACS en_US
dc.subject Keratoconus en_US
dc.title Corneal Ring Segments (intacs) for the Treatment of Asymmetrical Astigmatism of the Keratoconus. Follow-Up After 2 Years; en_US
dc.title.alternative Anneaux intracornéens (INTACS) pour le traitement de l'astigmatisme asymétrique du kératocône. Recul de plus de deux ans en_US
dc.type Article en_US
dspace.entity.type Publication

Files