Robust Passivity-Based Control Integrated with UDE Strategy for Grid-Tied Inverter

dc.contributor.author Uslu, U.A.
dc.contributor.author Aydemir, M.T.
dc.date.accessioned 2026-02-15T21:34:42Z
dc.date.available 2026-02-15T21:34:42Z
dc.date.issued 2025
dc.description.abstract Uncertainties caused by parametric variations, external disturbances, and modelling errors of grid-tied inverters (GTI) make it challenging to select a proper gain for the desired controller. The performance of conventional passivity-based controller (PBC), which depends on a strictly accurate mathematical model of the system, is seriously deteriorated due to having poor robustness against parametric uncertainties and disturbances. To this end, this paper presents an improved passivity-based controller scheme assisted with uncertainty and disturbance estimator (UDE) for GTI. The UDE that has been adopted into the proposed UDE-PBC loops is used to simultaneously estimate uncertainties, which can achieve robust control and provide zero steady-state error. Moreover, the proposed UDE-PBC enables a two-degree-of-freedom (2DOF) control structure; one dedicated for disturbance rejection and the other for closed-loop tracking response of GTI system. The effectiveness of the proposed control scheme has been verified in an experimental prototype of 2 kW and compared with the base controllers in terms of robustness and transient response. © 2025, Kauno Technologijos Universitetas. All rights reserved. en_US
dc.identifier.doi 10.5755/j02.eie.42821
dc.identifier.issn 1392-1215
dc.identifier.issn 2029-5731
dc.identifier.scopus 2-s2.0-105027251592
dc.identifier.uri https://doi.org/10.5755/j02.eie.42821
dc.identifier.uri https://hdl.handle.net/20.500.12469/7752
dc.language.iso en en_US
dc.publisher Kauno Technologijos Universitetas en_US
dc.relation.ispartof Elektronika Ir Elektrotechnika en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Grid-Tied Inverter (GTI) en_US
dc.subject Interconnection and Damping Assignment (IDA) en_US
dc.subject Passivity-Based Control (PBC) en_US
dc.subject Port-Controlled Hamiltonian (PCH) en_US
dc.subject Uncertainty and Disturbance Estimator (UDE) en_US
dc.title Robust Passivity-Based Control Integrated with UDE Strategy for Grid-Tied Inverter en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.scopusid 60320908000
gdc.author.scopusid 56373635300
gdc.bip.impulseclass C5
gdc.bip.influenceclass C5
gdc.bip.popularityclass C5
gdc.collaboration.industrial false
gdc.description.department Kadir Has University en_US
gdc.description.departmenttemp [Uslu] Umit Akin, Department of Electrical and Electronic Engineering, Alanya Alaaddin Keykubat University, Alanya, Antalya, Turkey; [Aydemir] M. Timur, Department of Electrical and Electronic Engineering, Kadir Has Üniversitesi, Istanbul, Turkey en_US
gdc.description.endpage 51 en_US
gdc.description.issue 4 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q3
gdc.description.startpage 40 en_US
gdc.description.volume 31 en_US
gdc.description.wosquality Q4
gdc.identifier.openalex W7117291896
gdc.index.type Scopus
gdc.oaire.accesstype GOLD
gdc.oaire.diamondjournal false
gdc.oaire.impulse 0.0
gdc.oaire.influence 2.4895952E-9
gdc.oaire.isgreen false
gdc.oaire.popularity 2.7494755E-9
gdc.oaire.publicfunded false
gdc.openalex.collaboration National
gdc.openalex.fwci 0.0
gdc.openalex.normalizedpercentile 0.66
gdc.opencitations.count 0
gdc.plumx.scopuscites 0
gdc.scopus.citedcount 0
gdc.virtual.author Aydemir, Mehmet Timur
relation.isAuthorOfPublication 3970d2e9-726a-42ce-96b5-7040860161dc
relation.isAuthorOfPublication.latestForDiscovery 3970d2e9-726a-42ce-96b5-7040860161dc
relation.isOrgUnitOfPublication 12b0068e-33e6-48db-b92a-a213070c3a8d
relation.isOrgUnitOfPublication 2457b9b3-3a3f-4c17-8674-7f874f030d96
relation.isOrgUnitOfPublication b20623fc-1264-4244-9847-a4729ca7508c
relation.isOrgUnitOfPublication.latestForDiscovery 12b0068e-33e6-48db-b92a-a213070c3a8d

Files