Continuous Glycemic Monitoring Enabled by a Wi-Fi Energy-Harvesting Wearable Sweat-Sensing Patch

dc.authorid Mirlou, Fariborz/0000-0003-0545-7504
dc.authorid Istif, Emin/0000-0003-4700-7050
dc.authorid Abbasiasl, Taher/0000-0002-8366-7737
dc.authorid Mirzajani, Hadi/0000-0001-7747-2389
dc.authorscopusid 57201195080
dc.authorscopusid 57214881443
dc.authorscopusid 55307447900
dc.authorscopusid 57200181969
dc.authorscopusid 57283991200
dc.authorscopusid 58261226000
dc.authorscopusid 58261226000
dc.authorwosid Mirzajani, Hadi/Q-1792-2017
dc.contributor.author Mirlou, Fariborz
dc.contributor.author Istıf, Emın
dc.contributor.author Abbasiasl, Taher
dc.contributor.author Mirzajani, Hadi
dc.contributor.author Istif, Emin
dc.contributor.author Akhtar, Muhammad Junaid
dc.contributor.author Cakir, Cengiz
dc.contributor.author Beker, Levent
dc.contributor.other Molecular Biology and Genetics
dc.date.accessioned 2024-06-23T21:38:11Z
dc.date.available 2024-06-23T21:38:11Z
dc.date.issued 2024
dc.department Kadir Has University en_US
dc.department-temp [Mirlou, Fariborz; Abbasiasl, Taher; Beker, Levent] Koc Univ, Dept Biomed Sci & Engn, Rumelifeneri Yolu, TR-34450 Istanbul, Turkiye; [Mirzajani, Hadi; Istif, Emin; Beker, Levent] Koc Univ, Dept Mech Engn, Rumelifeneri Yolu, TR-34450 Istanbul, Turkiye; [Istif, Emin] Kadir Has Univ, Fac Engn & Nat Sci, TR-34083 Istanbul, Turkiye; [Akhtar, Muhammad Junaid] Koc Univ, Dept Elect & Elect Engn, Rumelifeneri Yolu, TR-34450 Istanbul, Turkiye; [Cakir, Cengiz] Istanbul Tech Univ, Dept Elect & Commun Engn, 18 Maslak, TR-34469 Istanbul, Turkiye; [Beker, Levent] Koc Univ, Res Ctr Translat Res KUTTAM, Rumelifeneri Yolu, TR-34450 Istanbul, Turkiye en_US
dc.description Mirlou, Fariborz/0000-0003-0545-7504; Istif, Emin/0000-0003-4700-7050; Abbasiasl, Taher/0000-0002-8366-7737; Mirzajani, Hadi/0000-0001-7747-2389 en_US
dc.description.abstract Continuous monitoring of multiple physiological parameters, such as glucose levels, temperature, and heart rate variability (HRV) is crucial for effective diabetes management and mitigating the risks associated with hypoglycemic events. These events often occur without apparent symptoms, posing a challenge for diabetic patients in managing their condition. Therefore, a non-invasive wearable device capable of continuously measuring multiple body signals to predict hypoglycemic events would be highly beneficial. In this study, a wearable patch that continuously measures glucose, temperature, and HRV is presented. The device uses a novel power harvesting system to convert radiofrequency (RF) signals with the frequency of 2.45 GHz to direct current (DC) signals to extend the battery life for further continuous monitoring. The patch is small and has a conformal structure that can easily fit onto different body parts. The screen-printed glucose sensor demonstrates a sensitivity of 10.3 nA cm-2 mu M-1, a limit of detection (LOD) of 8.9 mu M, and a limit of quantification (LOQ) of 27 mu M. The device employs a photoplethysmography (PPG) module with a peak-finding algorithm to calculate the HRV values. In vivo experiments demonstrate the validation of the device's proper operation in glucose, HRV, and temperature measurement. This study introduces a wearable patch for diabetes management, employing a unique Wi-Fi energy harvesting system for extended battery life. The device's conformal structure enables effortless placement on the body, providing continuous monitoring of glucose, HRV, and temperature. The platform presents a non-invasive physiological monitoring approach that enhances diabetes care by offering real-time data in a compact and efficient design. image en_US
dc.description.sponsorship Scientific and Technological Research Council of Turkey (TUBITAK) [118C295, 120M363, HORIZON-TMA-MSCA-PF-EF-2021-101068646, 121Z184, 101043119]; Marie Sklodowska-Curie Postdoctoral Fellowship; European Research Council (ERC) [118C155]; [2210822] en_US
dc.description.sponsorship F.M., T.A., and L.B. were supported by The Scientific and Technological Research Council of Turkey (TUBITAK) through 2244 (#118C155), 2232 (#118C295), and 3501 (120M363) programs. H.M. acknowledges the support through a Marie Sklodowska-Curie Postdoctoral Fellowship (HORIZON-TMA-MSCA-PF-EF-2021-101068646, HAMP). E.I. acknowledges the support through The Scientific and Technological Research Council of Turkey (TUBITAK) 3501 (grant no. 121Z184) and 1512 (grant no. 2210822) programs. L.B. acknowledges European Research Council (ERC) (grant no. 101043119). Authors gratefully acknowledge Koc University Nanofabrication and Nano-characterization Center (N2Star) for infrastructure access. en_US
dc.identifier.citationcount 0
dc.identifier.doi 10.1002/admt.202301583
dc.identifier.issn 2365-709X
dc.identifier.issue 7 en_US
dc.identifier.scopus 2-s2.0-85184506251
dc.identifier.scopusquality Q1
dc.identifier.uri https://doi.org/10.1002/admt.202301583
dc.identifier.uri https://hdl.handle.net/20.500.12469/5763
dc.identifier.volume 9 en_US
dc.identifier.wos WOS:001158240900001
dc.identifier.wosquality Q1
dc.language.iso en en_US
dc.publisher Wiley en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.scopus.citedbyCount 3
dc.subject continuous monitoring en_US
dc.subject diabetes en_US
dc.subject energy harvesting en_US
dc.subject glucose sensor en_US
dc.subject heart rate en_US
dc.subject heart rate variability en_US
dc.subject wearables en_US
dc.title Continuous Glycemic Monitoring Enabled by a Wi-Fi Energy-Harvesting Wearable Sweat-Sensing Patch en_US
dc.type Article en_US
dc.wos.citedbyCount 3
dspace.entity.type Publication
relation.isAuthorOfPublication 08c8db76-4ea9-4e56-abe5-99f86e51286d
relation.isAuthorOfPublication.latestForDiscovery 08c8db76-4ea9-4e56-abe5-99f86e51286d
relation.isOrgUnitOfPublication 71ce8622-7449-4a6a-8fad-44d881416546
relation.isOrgUnitOfPublication.latestForDiscovery 71ce8622-7449-4a6a-8fad-44d881416546

Files