dc.description.abstract Objective: To evaluate the use of corneal ring segments (INTACS) for the treatment of asymmetrical astigmatism in keratoconus. Material and methods: This prospective study involved nine eyes of seven patients who were operated on between December 1998 and June 2000. A case of keratoconus with opacified cornea was excluded from this study. The patients chosen were contact lens-intolerant. The surgical intervention was carried out under topical anesthesia. The INTACS (Addition Technology) corneal ring insert was inserted approximately 68% of the peripheral corneal depth and was centered to the cone of the cornea. Results: No intraoperative complications occurred. We noted a flattening of the central cornea and a decrease in irregular astigmatism for all patients. Mean preoperative uncorrected visual acuity was less than 1/10. Postoperatively two eyes had an uncorrected visual acuity of 10/10 seven eyes showed an improvement from an uncorrected visual acuity of 2/10 to 7/10. Conclusion: We have observed that the flattening effect of INTACS inserts on the soft corneal keratoconic tissue and on the high astigmatic tissue seems greater than that produced in normal cornea. Implantation of INTACS resulted in a significant reduction in asymmetrical astigmatism of the keratoconus. en_US]
dc.identifier.citationcount 16
dc.identifier.endpage 830
dc.identifier.issn 0181-5512 en_US
dc.identifier.issn 0181-5512
dc.identifier.issue 8
dc.identifier.pmid 14586224 en_US
dc.identifier.startpage 824 en_US
dc.identifier.uri https://hdl.handle.net/20.500.12469/174
dc.identifier.uri https://www.semanticscholar.org/paper/%5BCorneal-ring-segments-(INTACS)-for-the-treatment-2-Tun%C3%A7-Deveci/ee0cf17d709cd6a98ae806257e7d4d34355bb634
dc.identifier.volume 26 en_US
dc.identifier.wos WOS:000186839000007 en_US
dc.language.iso fra en_US
dc.publisher Masson Editeur en_US
dc.relation.journal Journal Francais D Ophtalmologie en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Keratoconus en_US
dc.subject Intacts en_US
dc.subject Astigmatism en_US
dc.title Corneal Ring Segments (intacs) for the Treatment of Asymmetrical Astigmatism of the Keratoconus. Follow-Up After 2 Years en_US
dc.type Article en_US
dc.wos.citedbyCount 16
dspace.entity.type Publication

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Corneal ring segments (INTACS) for the treatment of asymmetrical astigmatism of the keratoconus. Follow-up after 2 years.pdf
Size:
267.88 KB
Format:
Adobe Portable Document Format
Description: